Equipotential bonding in hazardous areas

Non-sparking pipe clamps, clamps and accessories for hazardous areas for use in potentially explosive atmospheres.
Pipe Clamps for Ex Zones 1/21, 2/22

Pipe Clamps for Ex Zones 1/21, 2/22

Pipe clamp for electrically contacting pipes in Ex zones 1 and 2 (gases, vapours, mists) as well as Ex zones 21 and 22 (dusts). Non-sparking lightning equipotential bonding according to IEC/EN 62305-3.
  • For use in Ex zones 1 and 2 (gases, vapours, mists) as well as Ex zones 21 and 22 (dusts)
  • Tested according to explosion group IIB
  • Time-saving installation – no need to deactivate systems/areas for welding or drilling works

Parallel Connectors for Ex Zones 1/21, 2/22

Parallel Connectors for Ex Zones 1/21, 2/22

Parallel connector with spring washer for connecting round conductors/cables in Ex zones 1/21, 2/22. The clamps are secured against self-loosening in accordance with DIN EN 62305-3 Supplement 2.
Pipe Clamp GSG for Ex Zone 2/22

Pipe Clamp GSG for Ex Zone 2/22

Pipe clamp for electrically contacting pipes in Ex zone 2/22. The pipe clamp is secured against self-loosening according to DIN/EN 62305-3 Supplement 2.
Clamps for Ex Zone 2/22

Clamps for Ex Zone 2/22

Clamps with spring washer for connecting round / flat conductors in Ex zone 2/22. The clamps are secured against self-loosening according to DIN EN 62305-3 Supplement 2.
Connection clamps for steel girders for hazardous areas zone 2/22

Connection clamps for steel girders for hazardous areas zone 2/22

Heavy design; for connection to steel structures.
All connections secured against self-loosening:
  • Connection to the steel structure using adhesive-coated screws
  • Round conductor connection using spring washer

Non-sparking, Ex equipotential bonding bar for hazardous areas of zones 1/21, 2/22

Non-sparking, Ex equipotential bonding bar for hazardous areas of zones 1/21, 2/22

Non-sparking, Ex equipotential bonding bar for integrating metallic conductors and wires into the lightning equipotential bonding according to VDE 0185-305-3 (IEC 62305-3) as well as for protective and functional equipotential bonding according to DIN VDE 0100 Part 410/540.
Equipotential Bonding Busbars for Ex Zone 2/22

Equipotential Bonding Busbars for Ex Zone 2/22

Equipotential bonding busbars for protective and functional equipotential bonding according to IEC 60364-4-41/60364-5-54 and lightning equipotential bonding according to IEC/EN 62305-3. Screws are secured against self-loosening according to DIN EN 62305-3 Supplement 2 by means of a spring washer.
Equipotential Bonding on Cable Tray Systems for Ex Zone 2/22

Equipotential Bonding on Cable Tray Systems for Ex Zone 2/22

The equipotential bonding system is mounted on cable tray systems. All conductive system parts and electrical equipment are integrated in the Ex equipotential bonding by means of equipotential bonding plates and clamps as well as a closed ring equipotential bonding conductor.