DEHNcord
:quality(98)/www.dehn.nl/store/f/5760706/HDVORSCHAU/900445a1_16-9.jpg)
:quality(98)/www.dehn.nl/store/f/5760706/HDVORSCHAU/900445a1_16-9.jpg)
- Single-pole, two-pole or three-pole surge protective device with monitoring system and disconnector
- Visual fault indication
- Types with disconnection of the load circuit in the event of a fault and protection of the control phase
- Compact design also for outdoor use
- Can be fitted in junction boxes, flush-mounted systems, cable ducts and flush-type boxes
Details
:quality(98)/www.dehn.nl/store/f/5760707/HDVORSCHAU/900447a2.jpg)
:quality(98)/www.dehn.nl/store/f/5760707/HDVORSCHAU/900447a2.jpg)
DEHNcord 3P TT 275 FM
Compact three-phase arrester for for TT and TN-S systems.
1 Product
Artikelnr. 900439 DCOR 3P TT 275 FM
GTIN 4013364436053, CCT: 85363030, Brutogewicht: 129.38 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 + type 3 / class II + class III |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Max. continuous operating voltage (d.c.) (UC ) | 350 V |
Nominal discharge current (8/20 µs) [L-N] (In ) | 10 kA |
Max. discharge current (8/20 µs) [L-N] (Imax ) | 20 kA |
Nominal discharge current (8/20 µs) [N-PE] (In ) | 10 kA |
Max. discharge current (8/20 µs) [N-PE] (Imax ) | 40 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Approvals | KEMA |
DEHNcord L 2P
Two-pole surge arrester for all installation systems (1+1 configuration) and luminaires of protection class I; compact design.
2 producten
Artikelnr. 900430 DCOR L 2P 275
GTIN 4013364157286, CCT: 85363030, Brutogewicht: 73.00 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | 25 A gG |
Approvals | KEMA |
Artikelnr. 900432 DCOR L 2P 320
GTIN 4013364157309, CCT: 85363030, Brutogewicht: 74.00 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 320 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.75 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | 25 A gG |
Approvals | KEMA |
DEHNcord L 1P
Single-pole surge arrester for luminaires of protection class II; compact design.
2 producten
Artikelnr. 900431 DCOR L 1P 275
GTIN 4013364310827, CCT: 85363030, Brutogewicht: 60.00 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | 25 A gG |
Approvals | KEMA |
Artikelnr. 900433 DCOR L 1P 320
GTIN 4013364157316, CCT: 85363030, Brutogewicht: 61.00 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 320 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.75 kV |
Max. mains-side overcurrent protection | 25 A gG |
Approvals | KEMA |
DEHNcord L 2P SN1864
Surge arrester for luminaires of protection class II; compact design. With disconnection in the event of a fault.
1 Product
Artikelnr. 999906 DCOR L 2P SN1864
GTIN 4013364310926, CCT: 85363030, Brutogewicht: 70.50 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
DEHNcord L 2P SN1860
Surge arrester for all installation systems; compact design. With disconnection of the load circuit in the event of a fault.
1 Product
Artikelnr. 999937 DCOR L 2P SN1860
GTIN 4013364303195, CCT: 85363030, Brutogewicht: 86.00 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
DEHNcord L 2P 275 SO LTG
Surge arrester for all installation systems; compact design. With disconnection of the load circuit in the event of a fault.
1 Product
Artikelnr. 900446 DCOR L 2P 275 SO LTG
GTIN 4013364292970, CCT: 85363030, Brutogewicht: 62.50 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
Approvals | KEMA |
DEHNcord L 3P 275 SO LTG
Three-pole surge arrester for all installation systems; compact design. With disconnection of the load circuit in the event of a fault and protection of the control phase.
1 Product
Artikelnr. 900445 DCOR L 3P 275 SO LTG
GTIN 4013364280380, CCT: 85363030, Brutogewicht: 71.50 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
Approvals | KEMA |
SK EK480 G2S-2d LM DCOR
The EK480 fuse box is a high-quality product from Langmatz which stands out for its excellent workmanship and tried and tested features. The EK480 series meets all mechanical and electrical requirements and standards. This ensures the effective protection of luminaires with high-quality electronics against surges resulting from switching operations or nearby lightning strikes.
1 Product
Artikelnr. 900443 SK EK480 G2S-2d LM DCOR
GTIN 4013364394322, CCT: 85362010, Brutogewicht: 788.00 g, VPE: 20.00 Stk
Technische gegevens
Data of fuse box | |
Dimensions | 276 x 81 x 70 mm |
For masts with an inside diameter from | 89 mm |
Clamping technology | incoming: sliding clamp technology / outgoing: spring clamp technology |
Max. cross-section of connectable cable | 1 - 3 cables (4 or 5 x 16 mm2) |
Outgoing terminals | max. 2.5 mm2 |
Data of DEHNcord L 3P 275 SO LTG surge protective device | |
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating a.c. voltage [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
DEHNcord L 2P 275 SO LT
Two-pole surge arrester for TNC systems; compact design. With disconnection of the load circuit in the event of a fault and protection of the control phase.
1 Product
Artikelnr. 900435 DCOR L 2P 275 SO LT
GTIN 4013364292963, CCT: 85363030, Brutogewicht: 70.00 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-PEN] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-PEN] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
Approvals | KEMA |
DEHNcord L 3P 275 SO IP
Three-pole surge arrester for all installation systems; compact design. IP 65 degree of protection. With disconnection of the load circuit in the event of a fault and protection of the control phase.
1 Product
Artikelnr. 900447 DCOR L 3P 275 SO IP
GTIN 4013364282216, CCT: 85363030, Brutogewicht: 146.60 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
DEHNcord L 2P 275 SO IP
Two-pole arrester for all installation systems; compact design. IP 65 degree of protection. With disconnection of the load circuit in the event of a fault.
1 Product
Artikelnr. 900448 DCOR L 2P 275 SO IP
GTIN 4013364293007, CCT: 85363030, Brutogewicht: 139.90 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 5 kA |
Max. discharge current (8/20 µs) (Imax ) | 10 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Voltage protection level [N-PE] (UP ) | ≤ 1.5 kV |
Max. mains-side overcurrent protection | B 16 A |
DEHNcord R 3P
Surge arrester for electric Venetian blinds; compact design.
1 Product
Artikelnr. 900449 DCOR R 3P 275
GTIN 4013364320031, CCT: 85363030, Brutogewicht: 151.50 g, VPE: 1.00 Stk
Technische gegevens
SPD according to EN 61643-11 / IEC 61643-11 | type 2 / class II |
Max. continuous operating voltage (a.c.) [L-N] (UC ) | 275 V (50 / 60 Hz) |
Nominal discharge current (8/20 µs) (In ) | 2.5 kA |
Max. discharge current (8/20 µs) (Imax ) | 5 kA |
Voltage protection level [L-N] (UP ) | ≤ 1.5 kV |
Connector | Hirschmann STAK 3 / STAS 3 |